Designed as a smaller sibling to the Electrak HD actuator, these smart electric linear actuators pack a big punch relative to their compact size and dutifully perform in the harshest environments without the need for service or maintenance. Onboard controls open the door to a wide range of possibilities, including CAN bus options and low-level switching with or without position feedback.

Electrak MD Specifications:

Performance SpecificationsMDxxA025MDxxA050MDxxA100MDxxA200
Input Voltages (VDC)12 Vdc (tolerance: 9-16)
24 Vdc (tolerance: 18-32)
48 Vdc (tolerance: 38-60)
Min/Max Stroke Length: mm50/300 @ 50 ordering increments
Max Static/Dynamic Load: N (lbs)250 (56)500 (112)1000 (225)2000 (450)
Max No-Load Speed: mm/s (in/s)52 (2.04)28 (1.1)14.5 (0.57)7 (0.28)
Max Full-Load Speed: mm/s (in/s)43.8 (1.72)18.5 (0.73)11 (0.43)5.4 (0.21)

Full load duty cycle @ 25 ºC (77 ºF)

25
Screw/Nut TypeAcme/Lead
Operating temperature: ºC (ºF)-40 to +85 (-40 to +185)
Protection Class: static/dynamicIP67, IP69K / IP66
Restraining Torque: Nm (lbs)0
End Play (Max): mm(in)1.2 (0.047)
Actuator Weight (kg)1.1 @ 50mm
1.2 @ 100mm
1.3 @ 150mm
1.4@ 200mm
1.5 @ 250mm
1.6 @ 300mm
Salt Spray Resistance (hours)500

Electrak MD Feature Highlights:

  • Onboard electronics
  • Built-in J1939 or CANopen CAN bus
  • Overload protection
  • Electronic trip point calibration
  • End-of-stroke, voltage, current monitoring
  • Standard anti-rotation actuation
  • CE, RoHS, REACH (CU) compliant
  • Dynamic motor braking
  • Self-locking lead nut
  • Temperature monitoring
  • Temperature compensation
  • Flying lead cables

Electrak MD Electronics Options:

  • EXX: Monitoring System (EMS) only
  • EXP: EXX+Analog Position Output
  • LXX: EXX+Low Level Signal Switching
  • LLX: EXX+LXX+End of Stroke Output
  • LXP: EXX+LXX+Analog Position Output
  • CNO: Can Bus J1939 Control + Open Loop Speed Control
  • XXX = Internal End-of-Stroke Limit Switches
  • XXP = XXX + Analog (Potentiometer) Position Output
  • LLP = LLX + Analog (Potentiometer) Position Output
  • COO = CAN bus CANopen control + open loop speed control

Electrak MD Applications:

  • Automated Guided Vehicles
  • Logistics Trains • Workstations
  • Packaging Machines
  • Agricultural Vehicles
  • Agricultural Vehicles
  • Gardening and Landscaping Vehicles
  • Seeding, Watering and Fertilizing Machines

Contact us

Dénes Surányi

Project Engineer

+36 29 557 771

+36 70 623 3500

English

István Varga

Sales Engineer

+36 29 577 763

+36 70 391 3800

English

2
Electrak_MD_Actuator_bruk(3).pdf

Electrak_MD_Actuator_bruk(3).pdf

Electrak_MD_Installation_Operation_mnuk(2).pdf

Electrak_MD_Installation_Operation_mnuk(2).pdf