Pressure in the circuit increases proportional to increasing electric command signal

Screw-in cartridge proportional pressure relief valve, pilot operated.
Screw-in cartridge proportional pressure relief valve, pilot operated. The complete valve consists of a pilot stage - valve SR1P2-A2 and a main stage with connection thread 7/8-14 UNF. The valve maintains the constant pressure in the circuit proportional to the input command signal. The valve does not have a mechanical stroke limitation and thus cannot be used as a safety valve. Air bleeding is necessary for the correct function of the valve.
Installation: When possible, the valve should be mounted below the reservoir oil level. This will maintain oil in the actuator, preventing instability caused by air in the system. If possible, to achieve the best result, mount the valve vertically above the bleed screw and ensure proper air bleeding.
Note: back pressure in T-channel automatically increases the set cracking pressure of the valve in a ratio of 1:1.